Need assistance with selecting the correct solution to meet your specific requirements?
To see the Mobile Pipeline Blowdown and Cross Compression Solutions Brochure
BAUER GRU®42 XXL DUPLEX MOBILE PERFORMANCE
Inlet Pressure | Outlet Pressure | Compressor | System Performance | ||
---|---|---|---|---|---|
Actual Used Power | Flow Rate | Combined Flow Rate | |||
PSIG | PSIG | RPM | HP | SCFM | MMFCD |
100-30 | 110 | 3207 | 625.0 | 6193 | 8.9 |
20 | 110 | 3420 | 625.0 | 5071 | 7.3 |
10 | 110 | 3600 | 634.0 | 3740 | 5.4 |
5 | 110 | 3600 | 586.0 | 2950 | 4.2 |
1 | 110 | 3600 | 539.4 | 2318 | 3.3 |
0 | 110 | 3600 | 528.4 | 2161 | 3.1 |
Note: 1) All performance data for compressed gas inlet (suction conditions) is stated at Standard Conditions: Suction Pressure as Indicated, Gas Temperature of 68⁰ F (20⁰C), and RH of 0% 2) All performance data for the compressed gas outlet is stated at ISO 1217 Reference Conditions: Absolute Pressure at 364 ft (111m) elevation = 14.5 PSIG ( 1 Bar), Gas Temperature of 68⁰ F (20⁰C) and RH of 0% 3) All performance data are based on a typical well gas composition based on the following Mol percentages: Methane 97%, Nitrogen 1.0%, Carbon Dioxide 2%
EXAMPLE: PIPELINE BLOWDOWN TIMES (20 mile, 36 inch pipeline)
Pipeline Diameter | Pipeline Length | Pipeline Starting Pressure | Pipeline Residual Pressure | Draw-down Time | Draw-down Time |
---|---|---|---|---|---|
INCHES | MILES | PSIG | PSIG | HOURS | DAYS |
36 | 20 | 100 | 30 | 52 | 2d,4h |
36 | 20 | 100 | 15 | 67 | 2d,19h |
36 | 20 | 100 | 5 | 78 | 3d,6h |
36 | 20 | 100 | 0 | 83 | 3d,11h |