mail-icon
Need assistance with selecting the correct solution to meet your specific requirements?

pdf-icon
To see the Mobile Pipeline Blowdown and Cross Compression Solutions Brochure

BAUER GRU®42 XXL DUPLEX MOBILE PERFORMANCE

Inlet Pressure Outlet Pressure Compressor System Performance
Actual Used Power Flow Rate Combined Flow Rate
PSIG PSIG RPM HP SCFM MMFCD
           
100-30 110 3207 625.0 6193 8.9
20 110 3420 625.0 5071 7.3
10 110 3600 634.0 3740 5.4
5 110 3600 586.0 2950 4.2
1 110 3600 539.4 2318 3.3
0 110 3600 528.4 2161 3.1

Note: 1) All performance data for compressed gas inlet (suction conditions) is stated at Standard Conditions: Suction Pressure as Indicated, Gas Temperature of 68⁰ F (20⁰C), and RH of 0%  2) All performance data for the compressed gas outlet is stated at ISO 1217 Reference Conditions: Absolute Pressure at 364 ft (111m) elevation =  14.5 PSIG ( 1 Bar),  Gas Temperature of 68⁰ F (20⁰C) and  RH of 0%  3) All performance data are based on a typical well gas composition based on the following Mol percentages: Methane 97%, Nitrogen 1.0%, Carbon Dioxide 2%

EXAMPLE: PIPELINE BLOWDOWN TIMES (20 mile, 36 inch pipeline)

Pipeline Diameter Pipeline Length Pipeline Starting Pressure Pipeline Residual Pressure Draw-down Time  Draw-down Time
INCHES MILES PSIG PSIG HOURS DAYS
 
36 20 100 30 52 2d,4h
36 20 100 15 67 2d,19h
36 20 100 5 78 3d,6h
36 20 100 0 83 3d,11h