mail-icon
Need assistance with selecting the correct solution to meet your specific requirements?

pdf-icon
To see the Mobile Pipeline Blowdown and Cross Compression Solutions Brochure

BAUER C52.7 X-Fill PERFORMANCE (EACH SIMPLEX COMPRESSOR SYSTEM)

Compressor Inlet Pressure Compressor Outlet Pressure Compressor Actual Used Power Flow Rate Combined Flow Rate
PSIG PSIG RPM HP SCFM MMFCD
           
145 1450 1425 293 867 1.25
110 1450 1425 249 668 0.96
90 1450 1425 230 496 0.71
60 1450 1425 230 496 0.56

Note: 1) All performance data for compressed gas inlet (suction conditions) is stated at Standard Conditions: Suction Pressure as Indicated, Gas Temperature of 68⁰ F (20⁰C), and RH of 0%  2) All performance data for the compressed gas outlet is stated at ISO 1217 Reference Conditions: Absolute Pressure at 364 ft (111m) elevation =  14.5 PSIG ( 1 Bar),  Gas Temperature of 68⁰ F (20⁰C) and  RH of 0%  3) All performance data are based on a typical well gas composition based on the following Mol percentages: Methane 97%, Nitrogen 1.0%, Carbon Dioxide 2%