STANDARD SCOPE OF SUPPLY COMPRESSOR MODULE

  • BAUER breathing air purification system with SECURUS
  • BAUER PLC based controller with 7” color HMI touchscreen display
  • NEMA 4 rated electrical enclosure with UL® listed control panel
  • Compressor low oil pressure and high temperature safety shutdowns
  • Emergency stop push button and automatic start/stop control
  • Zero loss automatic condensate drain system with non-corrosive condensate reservoir and integrated float sensor and automatic “Full” indication and compressor shutdown
  • Inter-stage pressure gauges (locally mounted)
  • Vertically hinged front operations panel and lift-off side maintenance access doors
  • Inlet filter maintenance indicator
  • Unique hinged front operations panel

STANDARD SCOPE OF SUPPLY -  FILL STATION MODULE

  • Dual function cascade controls
  • Two (2) UN code stamped air cylinders installed in an integral rack
  • 3-way selector valve
  • NFPA 1901 2016 edition compliant 2 position containment fill station accommodates SCBA or SCUBA cylinders up to 31” overall length
  • Aesthetically pleasing cabinetry
  • Will work with any brand compressor
  • Packaged together

SYSTEM FOOTPRINT

VAC05 – VAC26:
DIMENSIONS L x W x H inches (mm)

  • 55” x 35” x 70” (1397mm x 737mm x 1778mm)

WEIGHT pounds (kg)

  • 1000 - 1400 lb (453.6 - 635 kg)

 

AVAILABLE ACCESSORIES (FACTORY INSTALLED)

  • CO monitoring system
  • B-Kool (floor mount only)
  • H2S monitoring system with audible alarm

TECHNICAL DATA

Model Charging Rate1 Number of Stages Motor FAD2 RPM Purification System
  scfm l/min   HP kW      
5000 PSIG (345 BAR)
VT-P/8-E1/E3 8.4 238 3 7.5 5.6 7 1250 P2 SECURUS
6000 PSIG (414 BAR)
VT-P/5-E1/E3 5 142 3 5 3.7 4 1050 P2 SECURUS
VT-P/10-E1/E3 9.7 275 4 7.5 5.6 8.1 1180 P2 SECURUS
VT-P/13-E1/E3 13 368 4 10 7.5 10.8 1420 P2 SECURUS

1) Based on recharging an 80 cubic foot tank from 500 to 3000 psig
2) Compressor capacity referenced to standard inlet conditions
E1 = Single phase electric, 230 VAC/60 Hz.
E3 = Three Phase Electric, 208/230/460 VAC/60 Hz.
Other voltages available on request.