Need assistance with selecting the correct solution to meet your specific requirements?
To see the entire I-Series Medium Pressure Flyer
STANDARD SCOPE OF SUPPLY
- 3-stage, air-cooled, pressure-lubricated, continuous-duty rated reciprocating compressor
- Electric motor with v-belt drive, belt guard, and belt tensioning device
- Automatic condensate drain with condensate collector (collector includes a switch for high condensate level)
- Automatic operation with PLC controller (includes operator keypad and text display for operation, maintenance, and troubleshooting)
- NEMA 4 rated electrical enclosure with UL listed control panel
- Fused control voltage transformer
- Hourmeter
- Pressure sensors for oil pressure and final pressure
- Temperature switch
- Emergency stop push button
- Audible alarm
- Ambient temperature range: 40° to 113° F
- 24-month warranty
TECHNICAL DATA
Model | Capacity FAD1 | Number of Stages | Motor | Drive | ||
SCFM | L/MIN | HP2 | kW | |||
400-1000 PSIG (24-69 BAR) | ||||||
B22.5 | 24-33 | 680-935 | 3 | 15-20 | 11-15 | E3 |
B23.4 | 48-61 | 1360-1728 | 3 | 30-40 | 22-30 | E3 |
B25.4 | 75 | 2125 | 3 | 50 | 37 | E3 |
B28.2 | 100-113 | 2832-3200 | 3 | 60-75 | 45-55 | E3 |
B28.33 | 200-240 | 5665-6800 | 3 | 12-150 | 93-110 | E3 |
1)Compressor capacity (FAD) is referenced to standard inlet conditions and 80% of the compressor's maximum working pressure. Tolerance +/- 5%.
2) 3-phase motors only, 60 Hz standard. 50 Hz available on request.
3) Maximum discharge pressure of 900 PSIG.
E1 = 230/1/60 E3 = 230 - 460/3/60 Other voltages and frequencies available upon request. Engine drives are available.