To enter the setup parameters of the FX-10DM text display:

1) Power the monitor by powering up the PLC
2) Press "FNC" and "ENT" at the same time to enter the System Mode
3) Scroll to option #3:MONITOR SET and press "ENT"
4) With the MONITOR SET screen displaying option 1:DISPLAY SET press "ENT"
5) Use the scroll keys and the "ENT" key to select and set the following options:

Line #Data addressData TypeDescription
No.1 D0 Message System Status
No.2 D200 Comment Pressure
No.3 D10 Message Fault Code
No.4 D202 Comment Temperature
No.5 D50 Message Hourmeter 1
No.6 D51 Message Hourmeter 2
No.7 D60 Message Runtime
No.8 D1220 Comment Next ACD


6) After setup complete, Press "CLR" 2 times to return to "SYSTEM MODE".
7) Use scroll keys to select 4: Other and press ENT
8) Use Scroll keys to select 5: Read Out Com and press ENT
9) Use down arrow to selet 0:Read and press ENT
10) Press "CLR" 2 times to return to "SYSTEM MODE 1:Entry Monitor" and press ENT.