Home > Products & Solutions > Breathing Air Systems > Firefighting > Engine Driven

Engine Driven

The ENGINE DRIVEN compressor for recharging SCBA or SCUBA cylinders combines compressor, purification system and engine drive. The frame's rugged design is specific to the requirements of the engine drive/compressor block assembly.

STANDARD SCOPE OF SUPPLY

  • BAUER Breathing Air Purification System
  • BAUER PLC based controller with four line text display
  • NEMA 4 rated electrical enclosure
    with hourmeter and UL® listed control panel with hourmeter
  • NEMA 4 rated enclosure with hourmeter and UL® listed electrical assembly
  • Compressor low oil pressure and high temperature safety shutdowns
  • Automatic condensate drain system with non-corrosive
    condensate resevoir and integrated float switch.
    Automatic "Full" indication and compressor shutdown
  • Interstage pressure gauges
  • Electric start package including electric clutch and speed control solenoid

AVAILABLE ACCESSORIES(factory installed)

  • Audible alarms for safety shutdowns
  • CO Monitor
  • Other accessories available on request

Diesel Drive Models

  • Closed loop water cooled diesel

DIMENSIONS L x W x H inches (mm)

  • H13-K26 63 x 49 x 46 (1600 x 1245 x 1168)
  • H35-K46 95 x 52 x 49 (2413 x 1320 x 1245)
  • K60 112 x 52 x 53 (2845 x 1320 x 1346)

WEIGHT pounds (kg)

  • 1300 - 3750(590 - 1700)

 

Technical Data

ModelCharging
Rate*
Number
of
Stages
MotorFAD**RPMPurification
System
 scfmI/min hpkW   
5000 psig(345 bar)
K20-G 21 595 4 20 15 17.5 1300 P5
K20-D 21 595 4 27 20 17.5 1300 P5
K26-D 26.4 748 4 27 20 22 1350 P5
K42-D 42 1190 4 44 33 35 1300 P10
K60-D 60 1700 4 60 45 50 1350 P12 SECURUS
6000 psig(414 bar)
H13-G 13 368 4 13.5 10 10.8 1420 P2 SECURUS
H13-D 13 368 4 18 13 10.8 1420 P2 SECURUS
H19-D 19.2 544 5 27 20 16 1050 P5 SECURUS
H25-D 25.2 714 5 27 20 21 1300 P5 SECURUS
H35-D 35.9 1017 4 44 33 29.8 1200 P10 SECURUS

*Based on recharging an 80 cubic foot tank from 500 to 3000 PSIG.
**Compressor capacity referenced to standard inlet conditions.
G=Gasoline engine drive     D=Diesel engine drive Alternate drives available.